Anaesthetic Management of Congenital Scoliosis Correction with an Atrial Septal Occluder: A Case Report
DOI:
https://doi.org/10.66636/gmj.v1.i4.a215Keywords:
Atrial Septal Occluder, Congenital Scoliosis, Neurophysiological Monitoring, Paradoxical Air Embolism, Prone Position, AnaesthesiaAbstract
Introduction: Congenital scoliosis is frequently associated with cardiac anomalies, and patients increasingly present for spinal surgery after transcatheter atrial septal defect (ASD) closure.
Case presentation: A 17-year-old girl with congenital thoracolumbar scoliosis (Cobb angle 48°) due to a butterfly vertebra and hemivertebra underwent multilevel posterior spinal fixation. Her ASD, detected incidentally during scoliosis evaluation, had been closed with a transcatheter occluder at 10 years of age. The metallic device delayed whole-spine magnetic resonance imaging until compatibility was confirmed. Anaesthetic management included invasive arterial monitoring, ultrasound-guided central venous cannulation with fluoroscopic tip confirmation, and somatosensory and motor evoked potential monitoring. The 6-hour prone procedure, with 1500 mL blood loss, was uneventful; she was extubated the next day without neurological deficit.
Conclusion: An ASD occluder demands early imaging clearance, echocardiographic surveillance, vigilance for paradoxical air embolism, cautious central venous access and a plan for prone resuscitation.
Keywords: Atrial Septal Occluder; Congenital Scoliosis; Neurophysiological Monitoring; Paradoxical Air Embolism; Prone Position; Anaesthesia.
References
1. Issac S, Das JM. Kyphoscoliosis. [Updated 2025 Jul 6]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. [cited 2026 Sep 27]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK562183/
2. Furdock R, Brouillet K, Luhmann SJ. Organ system anomalies associated with congenital scoliosis: a retrospective study of 305 patients. J Pediatr Orthop. 2019;39(3):e190–e194. doi:10.1097/BPO.0000000000001279 DOI: https://doi.org/10.1097/BPO.0000000000001279
3. Wang X, Yu Y, Yang N, et al. Incidence of intraspinal abnormalities in congenital scoliosis: a systematic review and meta-analysis. J Orthop Surg Res. 2020;15(1):485. doi:10.1186/s13018-020-02015-8 DOI: https://doi.org/10.1186/s13018-020-02015-8
4. Bas JL, Pérez S, Rubio P, et al. Incidence of cardiac anomalies in congenital vertebral deformity: systematic review and meta-analysis of 2910 patients. Eur Spine J. 2023;32(9):2967–2974. doi:10.1007/s00586-023-07817-y DOI: https://doi.org/10.1007/s00586-023-07817-y
5. Laratta JL, Ha A, Shillingford JN, et al. Neuromonitoring in spinal deformity surgery: a multimodality approach. Global Spine J. 2018;8(1):68–77. doi:10.1177/2192568217706970 DOI: https://doi.org/10.1177/2192568217706970
6. Feng B, Qiu G, Shen J, et al. Impact of multimodal intraoperative monitoring during surgery for spine deformity and potential risk factors for neurological monitoring changes. J Spinal Disord Tech. 2012;25(4):E108–E114. doi:10.1097/BSD.0b013e31824d2a2f DOI: https://doi.org/10.1097/BSD.0b013e31824d2a2f
7. Reysner M, Reysner T, Janusz P, et al. The influence of anesthesia on neuromonitoring during scoliosis surgery: a systematic review. NeuroSci. 2024;5(4):693–712. doi:10.3390/neurosci5040049 DOI: https://doi.org/10.3390/neurosci5040049
8. Liu YT, Guo LL, Tian Z, et al. A retrospective study of congenital scoliosis and associated cardiac and intraspinal abnormities in a Chinese population. Eur Spine J. 2011;20(12):2111–2114. doi:10.1007/s00586-011-1818-2 DOI: https://doi.org/10.1007/s00586-011-1818-2
9. Yuan N, Skaggs DL, Dorey F, et al. Preoperative predictors of prolonged postoperative mechanical ventilation in children following scoliosis repair. Pediatr Pulmonol. 2005;40(5):414–419. doi:10.1002/ppul.20291 DOI: https://doi.org/10.1002/ppul.20291
10. Chen K, Wang L, Gao Q, et al. Tranexamic acid can reduce blood loss in adolescent scoliosis surgery: a systematic review and meta-analysis. BMC Musculoskelet Disord. 2023;24(1):686. doi:10.1186/s12891-023-06811-1 DOI: https://doi.org/10.1186/s12891-023-06811-1
11. American Society of Anesthesiologists Task Force on Perioperative Visual Loss, North American Neuro-Ophthalmology Society, Society for Neuroscience in Anesthesiology and Critical Care. Practice advisory for perioperative visual loss associated with spine surgery 2019. Anesthesiology. 2019;130(1):12–30. doi:10.1097/ALN.0000000000002503 DOI: https://doi.org/10.1097/ALN.0000000000002503
12. Adler DH. Atrial septal defect treatment & management. Medscape [Internet]. New York: WebMD LLC; [updated 2015 Dec 6; cited 2026 Sep 27]. Available from: https://emedicine.medscape.com/article/162914-treatment
13. Jalal Z, Hascoet S, Baruteau AE, et al. Long-term complications after transcatheter atrial septal defect closure: a review of the medical literature. Can J Cardiol. 2016;32(11):1315.e11–1315.e18. doi:10.1016/j.cjca.2016.02.068 DOI: https://doi.org/10.1016/j.cjca.2016.02.068
14. Kim JS, Yeom SY, Kim SH, et al. Delayed left atrial perforation associated with erosion after device closure of an atrial septal defect. Korean J Thorac Cardiovasc Surg. 2017;50(2):110–113. doi:10.5090/kjtcs.2017.50.2.110 DOI: https://doi.org/10.5090/kjtcs.2017.50.2.110
15. Haji Mohd Amin MZ, Beng JTB, Young BTY, et al. A case of cardiac arrest due to air embolism during scoliosis surgery. J Orthop Surg (Hong Kong). 2019;27(2):2309499019840083. doi:10.1177/2309499019840083 DOI: https://doi.org/10.1177/2309499019840083
16. Wills J, Schwend RM, Paterson A, et al. Intraoperative visible bubbling of air may be the first sign of venous air embolism during posterior surgery for scoliosis. Spine (Phila Pa 1976). 2005;30(20):E629–E635. DOI: https://doi.org/10.1097/01.brs.0000182347.85827.0c
17. Pham Dang C, Péreon Y, Champin P, et al. Paradoxical air embolism from patent foramen ovale in scoliosis surgery. Spine (Phila Pa 1976). 2002;27(11):E291–E295. doi:10.1097/00007632-200206010-00025 DOI: https://doi.org/10.1097/00007632-200206010-00025
18. Maragkos GA, Davanzo J, Roberts SM, et al. Paradoxical air embolism without patent foramen ovale during craniotomy in the sitting position. Cureus. 2019;11(4):e4355. doi:10.7759/cureus.4355 DOI: https://doi.org/10.7759/cureus.4355
19. Anez C, Becerra-Bolaños Á, Vives-Lopez A, et al. Cardiopulmonary resuscitation in the prone position in the operating room or in the intensive care unit: a systematic review. Anesth Analg. 2021;132(2):285–292. doi:10.1213/ANE.0000000000005289 DOI: https://doi.org/10.1213/ANE.0000000000005289
20. Brown J, Rogers J, Soar J. Cardiac arrest during surgery and ventilation in the prone position: a case report and systematic review. Resuscitation. 2001;50(2):233–238. doi:10.1016/s0300-9572(01)00362-8 DOI: https://doi.org/10.1016/S0300-9572(01)00362-8
21. Ramirez JD, Tubog TD. Evaluating prone cardiopulmonary resuscitation techniques in the surgical settings: a systematic review of case studies. J Perianesth Nurs. 2025;40(3):725–737. doi:10.1016/j.jopan.2024.07.011 DOI: https://doi.org/10.1016/j.jopan.2024.07.011
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Dhiraj Chopra

This work is licensed under a Creative Commons Attribution 4.0 International License.
This article is published open access under the Creative Commons Attribution 4.0 International (CC BY 4.0) licence.
You are free to: share and adapt the work for any purpose, even commercially.
Conditions: provide appropriate credit to the authors and the Georgian Medical Journal (GMJ), link to the licence, and indicate if changes were made. Do not apply legal terms or technological measures that legally restrict others from doing anything the licence permits.
Licence: creativecommons.org/licenses/by/4.0 · Legal code: creativecommons.org/licenses/by/4.0/legalcode
Third-party material. Images or other content credited to a third party are not covered by CC BY 4.0; permission must be obtained from the rights holder for reuse beyond statutory exceptions.
Authors' rights. Authors retain copyright. First publication rights are granted to GMJ.
Data and code. Where provided, datasets or code may carry their own licences; please follow the licence stated in the article or repository record.